Skip to content
Vet Tech Practice

Study topics / Surgical nursing

Sterilization indicators: how to monitor an autoclave

Steam sterilization needs steam, pressure, temperature and time. You check each load three ways: mechanical readings (time, temperature, pressure), chemical indicators (outside tape shows a pack was processed, an internal indicator shows steam got inside), and biological indicators (spore tests, at least weekly), the only check that directly measures killing power.

How steam sterilization works: time, temperature and saturated steam

An autoclave sterilizes by putting every item in direct contact with steam at the right temperature and pressure for a set time. The CDC names four parameters: steam, pressure, temperature and time. Pressure matters because it is how the chamber reaches temperatures high enough to kill microbes quickly.[1]

Moist heat kills by permanently coagulating and denaturing the enzymes and structural proteins of microorganisms. The ideal steam is dry saturated steam with a dryness fraction of 97% or more. Air left in the chamber or load gets in the way of steam contact, so removing air is part of every cycle.[1]

Recognized minimum exposure times for wrapped supplies[1]

Sterilizer typeTemperatureMinimum exposure
Gravity displacement121°C (250°F)30 minutes
Prevacuum132°C (270°F)4 minutes

Gravity displacement vs prevacuum autoclaves

In a gravity displacement autoclave, steam enters at the top or sides. Steam is lighter than air, so it pushes the air down and out through the drain. Some air can stay in the load, which slows steam penetration into porous items.[1]

A prevacuum autoclave uses a vacuum pump or ejector to pull air out before steam goes in, so steam penetrates porous loads almost at once. Because it relies on that air removal, a prevacuum autoclave needs a daily air-removal test (the Bowie-Dick test), run in an empty chamber.[1],[2]

The three types of sterilization monitoring

No single check proves a load is sterile. You combine mechanical, chemical and biological monitoring, and each one answers a different question.[2],[3]

What each type of monitoring tells you[2],[4]

TypeWhat it checksWhen you get the answer
MechanicalCycle time, temperature and pressure from the chart, printout, gauges or displayDuring the cycle
ChemicalColor change in heat or chemical sensitive ink when set conditions are reachedWhen the cycle is complete
BiologicalWhether known resistant spores were killedAfter incubation

Mechanical monitoring: reading the printout and gauges

Mechanical monitoring means looking at the gauges, display, chart or printout and noting time, temperature and pressure for every load. For steam, the CDC describes a daily review of cycle time and temperature on the record chart or printout, plus pressure on the gauge.[2],[3],[4]

Correct readings do not prove sterility, but wrong readings can be the first sign of a problem. If the readings show the autoclave did not reach the required time, temperature or pressure, do not use the packs from that load.[3],[4]

Chemical indicator types: outside tape vs inside the pack

Chemical indicators use heat or chemical sensitive inks that change color when certain sterilization conditions are present. They are cheap and give a result as soon as the cycle ends, but they only show exposure to the process. They do not prove sterilization was achieved.[2],[4]

External indicators, such as indicator tape or special markings on the outside of a package, show that the package went through a cycle. That is all they show. An internal indicator goes inside every package to show that the sterilant actually got through to the instruments. If the internal indicator cannot be seen from outside, use an external one as well.[2],[3],[4]

Internal indicators come in two kinds. A single-parameter indicator reports on only one condition, such as time or temperature. A multiparameter indicator is designed to react to two or more, such as time, temperature and the presence of steam.[4]

Check the indicator as soon as you take a package out of the autoclave. If either the internal or external indicator suggests poor processing, do not use the item.[2],[3]

Biological indicators: how spore tests work

A biological indicator, or spore test, holds highly resistant bacterial spores. It is the only process indicator that directly measures how well a cycle kills microorganisms, which is why it is the most accepted method of monitoring. For steam, the spores are Geobacillus stearothermophilus, incubated at 55 to 60°C after the cycle.[2],[4]

Run a spore test at least weekly, and in every load that contains an implant. Ideally, hold implants until the spore test comes back negative. Busy autoclaves can be tested daily to catch faults sooner.[2],[3]

Each test uses a matching control: an indicator from the same lot that is not put through the cycle but is incubated alongside the test. The control should grow, because that proves the spores were alive and the incubator worked. Growth in the processed test indicator is a positive result.[2],[3],[4]

What a failed biological indicator means

A positive spore test means spores survived the cycle. If mechanical and chemical indicators looked normal, a single positive result probably does not mean the autoclave is broken, but it still has to be followed up.[3]

CDC's dental guidance says to take the autoclave out of service, review your sterilization procedures, and repeat the spore test right away using the same cycle.[3]

CDC's protocol for hospital steam sterilizers asks for more: repeat the spore test in three consecutive cycles, and return the autoclave to service only if all three are negative.[5]

Recall and quarantine any implants from the load until they are shown to be sterile. Other items do not always need recall.[3]

If the repeat testing is also positive, the autoclave stays out of use until it is inspected or repaired and then passes spore tests in three consecutive cycles. Where possible, recall and re-sterilize items from suspect loads back to the last negative spore test.[2],[3]

These checks come from CDC guidance written for hospitals and dental offices, which is why implants and dental settings appear in it.[2],[3]

Ethylene oxide and gas plasma use their own indicators

Low temperature methods are monitored with their own biological indicators. Ethylene oxide uses Bacillus atrophaeus spores, and hydrogen peroxide gas plasma uses Geobacillus stearothermophilus spores. Mechanical monitors in clinical ethylene oxide units cannot measure gas concentration or humidity. For these methods, the CDC advises treating any positive spore test as a sterilizer malfunction.[2]

Worked examples

Example 1: A short cycle on the morning printout

You run a load of wrapped feline neuter packs in a gravity displacement autoclave. The printout shows the chamber held 121°C for 22 minutes, and the tape on every pack has changed color.

  1. Step 1: Find the standard: at 121°C in a gravity displacement sterilizer, wrapped supplies need at least 30 minutes.[1]
  2. Step 2: Compare: 22 minutes is short of 30, so the mechanical reading shows the cycle did not meet the required time.[1],[3]
  3. Step 3: Weigh the tape: external tape only shows the packs went through a cycle, not that they are sterile.[2]

Answer

Do not use the packs; reprocess them. A failed mechanical reading means the load cannot be trusted, and changed tape does not outweigh it.[1],[2],[3],[4]

Example 2: Does this pouch need tape?

You are packaging a single instrument for a cat spay in a peel pouch with a clear plastic face. A multiparameter strip goes inside, and you can read it through the plastic. A coworker asks whether the pouch also needs indicator tape.

  1. Step 1: Every package gets an internal indicator, to show the sterilant reached the instrument inside.[3],[4]
  2. Step 2: An external indicator is needed as well only when the internal one cannot be seen from outside.[3],[4]
  3. Step 3: Here the strip is visible through the clear face, so it does both jobs.[3],[4]
  4. Step 4: When the cycle ends, check the strip as soon as you take the pouch out.[3]

Answer

No tape is needed for this pouch, because the internal strip can be read from outside. A wrapped pack that hides its internal indicator would need an external one too.[3],[4]

Example 3: A spore test control that did not grow

On Friday you read the weekly spore test from the autoclave. The processed vial shows no growth, but the control vial from the same lot also shows no growth.

  1. Step 1: The control was never put through the cycle, so it should grow. Its growth is what shows the spores were alive and the incubator worked.[2],[4]
  2. Step 2: No growth in the control means neither of those was confirmed.[2]
  3. Step 3: So the clear processed vial tells you nothing about whether the cycle killed the spores.[2],[4]

Answer

You cannot count this as a passing spore test. The control has to grow before a clear processed vial means anything, so the test needs repeating.[2],[4]

Common mistakes

Practise it

Sources

  1. [1]CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities: Steam Sterilization
  2. [2]CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities: Sterilizing Practices
  3. [3]CDC, Best Practices for Sterilization Monitoring in Dental Settings
  4. [4]CDC, Guidelines for Infection Control in Dental Health-Care Settings, 2003 (MMWR)
  5. [5]CDC, Table 12: Suggested protocol for management of positive biological indicator in a steam sterilizer

Checked against the sources listed, November 21, 2026. Spotted an error? Email support and it goes in the corrections log.

One order, 90 days, nothing renews

Two free tests of 25 questions to try first. Paid access adds 476 practice questions and three timed mock exams, written up the same way.

OrdersVet Tech Practice · 90-day pass

  • 476 practice questions across all 10 VTNE domains, by domain or mixed. Tutor mode explains as you go; timed mode saves feedback for the end.
  • 3 timed mock exams 170 questions each, 3 hours on a clock that keeps running, with different questions in each and none shared with practice.
  • Every answer explained with a note on each wrong option and the source it was checked against.
  • Results by domain and a full answer review after each mock, plus bookmarks and daily goals.
  • Sign in by email link with no password, on any device.

Duration and cost

$119USD

  • One payment, 90 days of access
  • No subscription, nothing to cancel
  • Full refund within 7 days if you have answered fewer than 50 questions and not started a mock
Or try 25 free questions first
  • Buyers in Canada pay GST/HST on top. Both free tests stay free.
  • The three mock exams have different questions. Once you have taken all three, a retake repeats questions you have seen.
  • Scores are practice counts, not a prediction of your VTNE result.
  • Secure checkout by Stripe. Your card statement shows TENSORHUB, the company that runs this site. By buying you agree to the terms.