Blood smears: how to make, stain and read a wedge smear
Spread a small drop of well-mixed anticoagulated blood with a second slide held at 30 to 45 degrees, air-dry it, and dip it through a quick Romanowsky stain. Do your 100-cell differential, platelet estimate and red cell morphology in the monolayer, and use the feathered edge to look for platelet clumps and large cells.
How to make a wedge blood smear, step by step
Make the smear as soon as you collect the sample, because blood stored in the tube changes over time. Gently rock the blood tube first so the cells are evenly spread, then work quickly: a drop left sitting for more than a few seconds lets cells settle before you spread it.[1],[5]
Put a small drop of blood near one end of a clean slide. Place the short edge of a second slide, the spreader, in front of the drop at an angle of about 30 to 45 degrees. Pull it back into the drop and let the blood run along its edge. Then push it forward along the slide in one fast, gentle, smooth motion, keeping even pressure and not lifting the spreader until you reach the end.[1],[3]
Dry the smear quickly by waving it in the air or with a hair dryer. Never heat fix it and never wipe it. Label the slide with the patient's identification.[1],[3],[4]
Smooth, with no ripples from a jerky push and no holes
Length
Covers at least two thirds of the slide
Finish
Ends before the far end of the slide in a feathered edge with a rainbow sheen
Thickness
Thin enough that part of it is one red cell thick
Fixing a smear that is too thick or too thin
Drop size, spreader angle and speed all change the result. If the smear is too thick or too short, try a lower spreader angle or a smaller drop. If it is too thin or too long, raise the angle. Streaks usually mean the spreader edge needs cleaning.[3]
The patient's blood matters too. For an anemic animal, increase the angle so the blood spreads properly. For a hemoconcentrated animal, most often a dehydrated one, decrease the angle.[1]
How to stain a blood smear with a quick Romanowsky stain
Most stains used in veterinary medicine are Romanowsky-type quick stains such as Diff-Quik. These kits only need you to dip the slide through three solutions in turn, starting with a fixative. Follow the manufacturer's directions for timing. A thin smear may need less time, and a thick one may need longer, especially in the last (blue) solution.[4],[5],[6]
Make sure the slide is fully dry before it goes in, since water can remain even when it looks dry. No extra fixing is needed before you stain an air-dried smear.[6]
Keep the jars tightly capped when not in use, so the solutions do not evaporate and the fixative does not pick up water from the air. Do not top off a low jar. When the level drops or the staining gets worse, empty, clean and dry the jars and refill them with fresh stain.[5]
Poorly kept stain causes two common artifacts. Water in the fixative leaves refractile marks that flash as you focus up and down and can be mistaken for red cell inclusions. Old stain or poor rinsing leaves stain precipitate, which you will see focused above or below the cells rather than level with them.[5]
The feathered edge, monolayer and body: where to look
A good smear from a healthy animal has three zones. The thick body is near the drop. The feathered edge is the thin far end of the smear. The monolayer lies between them, and there red cells and white cells are evenly spread.[1],[2]
Do your 100-cell white cell count, platelet estimate and red cell morphology in the monolayer. As you count, follow the curve of the monolayer rather than tracking straight across the slide.[1],[2]
Scan the feathered edge too. Large cells collect there, and it is where you check for platelet clumps. The body can hint at agglutination or rouleaux, but confirm either one in the monolayer.[1],[2]
How to do a manual differential count
In the monolayer, identify and tally 100 white cells by type. The white cells should be well spread, not bunched at the feathered edge. Your tally gives the percentage of each type. If you see nucleated red cells, record how many you see per 100 white cells as you go.[2],[7]
Percentages alone are not meaningful. Convert each one to an absolute count by multiplying the percentage by the total white cell count, and interpret the absolute numbers.[4],[7]
How to do a platelet estimate from a blood smear
Using the 100x oil immersion lens in the monolayer, count the platelets in 10 fields and average them. Multiply the average by 15,000 to get an estimated platelet count per microliter. Treat this as a rough guide, not an exact count.[8]
Always look for platelet clumps, because clumps lower the platelet count whatever the method. Scan the slide for clumps before you report platelet numbers as low. An estimate inside the species reference interval is reported as adequate.[4],[8]
Recognising the white blood cell types
On a Romanowsky stain, each normal white cell has a few features that set it apart. Dog eosinophil granules vary a lot in size, number and shape, and in greyhounds and other sighthounds eosinophils may show no visible granules, only gray cytoplasm and vacuoles.[4],[9]
Normal white cells on a quick-stained smear[4],[9]
Cell
Key features
Segmented neutrophil
Lobulated nucleus; in many species, a constricted or knobbly nucleus rather than distinct lobes
Band neutrophil
Unsegmented nucleus with smooth, parallel or nearly parallel sides
Lymphocyte
Smallest white cell; round nucleus with dense chromatin and a thin rim of light blue cytoplasm
Monocyte
Usually the largest; round, kidney-shaped or lobulated nucleus with lacy chromatin; blue-gray cytoplasm, sometimes vacuolated
Eosinophil
Prominent pink granules
Basophil
Blue to purple granules on a Romanowsky stain; in cats, many small pale lavender granules; in dogs, a long ribbon-like nucleus and gray to lavender cytoplasm
Common red blood cell morphology terms
Judge red cell shape in the monolayer. Some changes are artifacts: spherocytes can appear falsely at the feathered edge, and echinocytes can come from stored blood or too much anticoagulant. To tell rouleaux from agglutination, dilute the blood with saline: rouleaux disperses, while agglutination usually does not.[2],[10]
2Step 2: Average them: 110 divided by 10 fields = 11 platelets per field.[8]
3Step 3: Multiply: 11 x 15,000 = 165,000 platelets per microliter.[8]
4Step 4: Scan the feathered edge for clumps before reporting the number.[2],[4]
Answer
The estimate is about 165,000 per microliter. It is reported as adequate if it falls inside the reference interval for dogs, after you rule out clumps.[2],[4],[8]
Example 3: Turning a cat's differential into absolute counts
A cat's total white cell count is 14,000 per microliter. In 100 white cells you count 70 segmented neutrophils, 20 lymphocytes, 6 monocytes and 4 eosinophils, plus 2 nucleated red cells.
1Step 1: Check the tally adds to 100 white cells: 70 + 20 + 6 + 4 = 100. Record the 2 nucleated red cells per 100 white cells separately.[7]
2Step 2: Neutrophils: 0.70 x 14,000 = 9,800 per microliter.[4],[7]
3Step 3: Lymphocytes: 0.20 x 14,000 = 2,800. Monocytes: 0.06 x 14,000 = 840. Eosinophils: 0.04 x 14,000 = 560.[4],[7]
Answer
The absolute counts are 9,800 neutrophils, 2,800 lymphocytes, 840 monocytes and 560 eosinophils per microliter. These, not the percentages, are what get interpreted.[4],[7]
Common mistakes
XCounting white cells at the feathered edge: do the 100-cell differential in the monolayer, where white cells are evenly spread.[2],[7]
XReporting low platelets without scanning for clumps: clumps lower the count, so check the slide, including the feathered edge, first.[2],[4],[8]
XHeat fixing a smear before staining: air-dry it instead, because fixing is not needed and may interfere with staining quality.[1],[6]
XTopping off quick stain jars: when the level falls or staining fades, empty, clean and refill them with fresh solution.[5]
XCalling spherocytes from the feathered edge: they can appear there as an artifact, so judge red cell shape in the monolayer.[2],[10]
XReporting a differential only as percentages: convert each cell type to an absolute count using the total white cell count.[4],[7]